The Journal of Heart and Lung Transplantation
International Society for Heart and Lung Transplantation.
Brief Communication|Articles in Press

Effects of Intra-Aortic Balloon Pump delayed deflation timing on carotid blood flow and cardiac mechanics: An ultrasound and haemodynamic study

Published:December 11, 2022DOI:https://doi.org/10.1016/j.healun.2022.12.007
      Intra-Aortic Balloon Pump (IABP) efficacy is critically affected by the inflation/deflation timing. Balloon deflation may cause a sucking effect, and a steal phenomenon on carotid flow. Delaying IABP deflation reduces the degree of this flow reversal, but at the same time exposes patients to the risk of increased proto-systolic afterload with detrimental effects on the LV. The purpose of this study was to investigate the effects of a delayed IABP deflation timing on cerebral blood flow and LV hemodynamics, by means of simultaneous carotid artery ultrasonography, trans-thoracic echocardiography and central aortic pressure analysis. Delaying IABP deflation trigger to the beginning of QRS effectively increased the cerebral blood flow by 20%, mostly by reducing the reverse component flow caused by the diastolic balloon deflation. Extending the deflation to the early systole was safe and favourably impacted on cardiac mechanics, increasing CO by 15% without prolonging LV isovolumetric contraction and ejection phases.

      KEYWORDS

      Abbreviations:

      ADP (augmented diastolic pressure), ASP (assisted systolic pressure), CO (cardiac output), EDP (end-diastolic pressure), IABP (intra-aortic balloon pump), LV (left ventricle), VTI (velocity-time integral)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to The Journal of Heart and Lung Transplantation
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Baldetti L
        • Pagnesi M
        • Gramegna M
        • et al.
        Intra-Aortic Balloon pumping in acute decompensated heart failure with hypoperfusion: from pathophysiology to clinical practice.
        Circ Heart Fail. 2021; 14e008527
        • Schutt RC
        • Bhimiraj A
        • Estep JD
        • Guha A
        • Trachtenberg BH
        • Garami Z
        Deflation timing influences Intra-Aortic Balloon Pump-Mediated carotid blood flow reversal: a case report.
        Circ Heart Fail. 2016; 9e003474
        • Kern MJ
        • Aguirre FV
        • Caracciolo EA
        • et al.
        Hemodynamic effects of new intra-aortic balloon counterpulsation timing methods in patients: a multicenter evaluation.
        Am Heart J. 1999; 137: 1129-1136
        • Schreuder JJ
        • Maisano F
        • Donelli A
        • et al.
        Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction.
        Ann Thorac Surg. 2005; 79: 872-880
        • Pfluecke C
        • Christoph M
        • Kolschmann S
        • et al.
        Intra-aortic balloon pump (IABP) counterpulsation improves cerebral perfusion in patients with decreased left ventricular function.
        Perfusion. 2014; 29: 511-516