The Journal of Heart and Lung Transplantation
Volume 27, Issue 5 , Pages 514-521, May 2008

Coronary Flow Reserve Measurement Detects Transplant Coronary Artery Disease in Pediatric Heart Transplant Patients

Department of Congenital Heart Defects/Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany.

Received 2 November 2007; received in revised form 31 January 2008; accepted 6 February 2008.

Background

Cardiac allograft vasculopathy (CAV) in patients who have undergone heart transplantation leads to graft dysfunction and is still the major concern for long-term survival. Evaluation of coronary flow velocity reserve (CFR) has been established for diagnosis of CAV. Systemic application of adenosine vs intracoronary testing for CFR has been validated in adults; however, its accuracy in pediatric patients has not yet been proven.

Methods

CFR was prospectively measured in 33 clinically asymptomatic pediatric heart transplant recipients. CFR measurements were made in the left anterior descending (LAD) artery using a 0.014-inch Doppler FloWire (Cardiometrics). CFR was defined as the ratio of hyperemic (after adenosine injection) to basal (before adenosine) average peak velocity (APV). Adenosine (Adrekar) was administered by intracoronary (15 or 30 μg bolus) and systemic (0.1 mg/kg) injection in each patient. Epicardial CAV was evaluated in coronary angiograms (Stanford criteria) and microvasculopathy was diagnosed in endomyocardial biopsies (evidence of luminal stenosis) blinded to clinical data.

Results

Thirty-three patients were included in this study. Their median age (range) was 11.9 (1.4 to 17) years and median post-transplant time 4.3 (1 to 11.7) years. Seventeen of the 33 patients had epicardial CAV (mainly peripheral obliterations or B1 and B2 lesions) and microvascular CAV. Epicardial CAV only was found in 4 patients and microvasculopathy only was present in only 1 patient. CFR was significantly reduced in patients with epicardial CAV and microvasculopathy when compared with patients without any signs of CAV: 206 ± 53 vs 276 ± 39 (p < 0.001) for the systemic application and 213 ± 50 vs 271 ± 45 (p = 0.004) for the intracoronary application.

Conclusions

CFR and coronary vasoreactivity to adenosine are decreased in pediatric patients with CAV and correlate with histopathologic and angiographic evidence of microvascular disease. Measurement of CFR with intracoronary and systemic application of adenosine is comparable, while systemic application is necessary for non-invasive measurement of CFR in pediatric patients.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1053-2498(08)00138-1

doi:10.1016/j.healun.2008.02.005

The Journal of Heart and Lung Transplantation
Volume 27, Issue 5 , Pages 514-521, May 2008