Initial Experience With Non-thoracic, Extraperitoneal, Off-pump Insertion of the Jarvik 2000 Heart in Patients With Previous Median Sternotomy

Division of Cardiopulmonary Transplantation, Texas Heart Institute at St. Luke’s Episcopal Hospital, Houston, Texas

Received 8 August 2005; received in revised form 7 December 2005; accepted 10 December 2005. published online 07 April 2006.

Background

Successful implantation of left ventricular assist devices (LVADs) in patients with previous median sternotomy remains challenging.

Methods

Seven patients underwent implantation of a Jarvik 2000 Heart by an extrathoracic, extraperitoneal, sub-costal surgical approach, which allows easy exposure of the diaphragmatic surface of the heart and the supraceliac aorta. All patients were at very high risk and were receiving high doses of inotropic agents to maintain their cardiac function. All had undergone prior median sternotomy. We compared data for blood loss and intensive care unit (ICU) stay with those of 15 patients in whom the HeartMate I vented electric LVAD was placed through a re-do sternotomy incision.

Results

All 7 patients survived the surgical procedure for implantation of the Jarvik 2000. All 7 patients were rapidly rehabilitated and had a short stay in the ICU (mean 3.3 days, range 1 to 8 days), as compared with the re-do HeartMate patients (mean 10.3 days, range 3 to 33 days) (p = 0.005). The average 12-hour blood loss was 635 ml in the Jarvik patients compared with 2,405 ml in the re-do HeartMate patients (p = 0.028). The cardiac index improved significantly in all Jarvik patients.

Conclusions

The extrathoracic, extraperitoneal, sub-costal surgical approach is less invasive than a median sternotomy and allows the Jarvik 2000 to be implanted quickly and without cardiopulmonary bypass (CPB). By avoiding CPB and an extensive mediastinal dissection, bleeding is decreased in these hypocoagulable patients with compromised end-organ function. The decreased operative morbidity and mortality associated with this technique may allow consideration of the Jarvik 2000 Heart for safe and effective implantation in home-bound New York Heart Association (NYHA) Class III and IV patients.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1053-2498(06)00003-9

doi:10.1016/j.healun.2005.12.003

The Journal of Heart and Lung Transplantation
Volume 25, Issue 5 , Pages 499-503, May 2006